For the complete documentation index, see llms.txt. This page is also available as Markdown.

Processor failover

Processors can function as redundant pairs: one as Main and the other as Backup. Set up these pairs in Settings → Processors. Failover status does not influence processor health, although processor health can initiate automatic failover.

Automatic failover

Automatic failover requires an assigned Backup Processor. HOLOPLOT Control switches to the other Processor when:

  • The active Processor health becomes 🟠 Error or 🔴 Critical.

  • The active Processor stops streaming audio.

  • The active Processor stops responding before the failover timeout expires.

A short timeout (up to 10s) applies before switching. Recovery during that period cancels the pending failover. The target Processor must be healthy.

Manual failover

An assigned Backup Processor enables manual failover. Open Settings → Processors. Open the pair’s three-dot menu. Then select Force failover.

Manual failover takes effect immediately. It can switch in either direction.

The Force failover action in the Processor pair menu
Manual failover

Find failover events

Failovers appear as System events in the Event Log. Filter the log by System. See the Event Log for every failover event.

Last updated

Was this helpful?