Managing and operating Macros
Use Macros to make safe, section-based tuning changes across groups of beams in HOLOPLOT Control. Macros let operators adjust groups of beams with a small set of controls. Use them to make fast, safe changes without editing beams one by one.

What Macros are
From OS 2.6, Macros add a separate DSP layer in HOLOPLOT Control. Macro changes do not overwrite the original beam tuning. Resetting Macros returns the section to its baseline state. Beam tuning and system design values stay unchanged.
Each Macro section can include up to three controls:
Gain
Low Shelf
High Shelf
A system designer first creates sections and defines the beam operating ranges. Operators can then adjust those sections during rehearsal, soundcheck, or show operation.
Key terms
Section: a named group of beams inside a preset layer. Each beam can belong to one section only.
Beam Operating Ranges: per-beam limits for Gain, Low Shelf, and High Shelf.
Effective Range : the narrowest shared range across all beams in a section.
Macro Snapshots : saved Macro states for a preset.
When to use Macros
Use Macros when you need fast adjustments across an area or Function Group.
Typical use cases include:
Raising or lowering gain in a venue area
Applying small tonal changes to a beam group
Switching between show states with saved snapshots
Do not use Macros for:
Detailed beam tuning
System design changes
Set up Macros
Macro setup is done in Settings. This step is usually handled by a system designer or commissioner.
There are two setup tasks:
Define operating ranges
Create sections
Define operating ranges

Operating ranges define how far each Macro control can adjust a beam.
Go to Settings › Macros › Operating Ranges
Choose a grouping view. Preset Layers is the default.
Select one or more beams if you want to edit in bulk.
Set the value range for each beam:
Gain: min / max
Low Shelf: min / max gain / frequency / Q
High Shelf: min / max gain / frequency / Q
Default values are:
Gain
-12 dBto+3 dBLow Shelf
-6 dBto+3 dBat100 Hz,Q 0.7High Shelf
-6 dBto+3 dBat10 kHz,Q 0.7
Changes are saved immediately. There is no save button.
If a gain maximum exceeds the allowed total gain, HOLOPLOT Control flags the value and shows the permitted maximum.
Create sections

Sections group beams into operator-facing controls.
Go to Settings › Macros › Sections.
Select the required Preset Layer.
Click Add Section.
Enter a section name.
Enable the controls you want to expose:
Gain
Low Shelf
High Shelf
Select the beams for the section. You can use:
Function Groups
Arrays
Module Groups
Target Zones
Manual
Click Save.
Each beam can belong to one section per preset layer. If a beam is already assigned, you must move it or skip it.
If a preset layer is used in multiple presets, the section appears in each of them. Macro values still remain independent per preset.
Delete or edit sections
Use the section menu (⋮) to edit or delete a section.
You cannot edit or delete a section if a snapshot uses it. Delete the snapshot first.

Use Macros in tuning
Operators use Macros from the Tuning section.

Adjust the knobs

Go to Tuning › Macros.
Select a section card for the active preset.
Adjust the available controls:
Gain
Low Shelf
High Shelf
Drag the knob, scroll on it, or enter a value directly.
To reset one control, double-click the knob. To reset the full section, click Reset.
Each control stops at the section's effective range. The control cannot exceed that limit.
View details
Open the section menu (⋮) and select View detail.
The detail drawer shows:
The beams assigned to the section
The effective range for each Macro control
Save and restore Macro snapshots
Macro snapshots let you store and recall the section's knob positions for a preset.
Save a snapshot

In the snapshot bar, click Save to overwrite the current snapshot.
Click Save As to create a new snapshot.
Enter a name and optional notes.
Lock the snapshot if you want to prevent accidental overwrite.
A trailing * next to the snapshot name means there are unsaved changes.
Restore a snapshot

Open the snapshot dropdown.
Select the snapshot you want to load.
Compare it with the current state if needed.
Load the snapshot.
Restoring a Macro snapshot applies:
Section knob values
Section bypass state
Restoring a Macro snapshot does not apply:
Section membership
Operating ranges
Section names
Mute or Solo states
If a snapshot includes a section, delete the snapshot before changing that section or its beams.
Last updated
Was this helpful?